International
Tables for
Crystallography
Volume C
Mathematical, physical and chemical tables
Edited by E. Prince

International Tables for Crystallography (2006). Vol. C, ch. 7.3, pp. 644-652
https://doi.org/10.1107/97809553602060000606

Chapter 7.3. Thermal neutron detection

P. Converta and P. Chieuxa

aInstitut Laue–Langevin, Avenue des Martyrs, BP 156X, F-38042 Grenoble CEDEX, France

References

Abele, R. K., Allin, G. W., Clay, W. T., Fowler, C. E. & Kopp, M. K. (1981). Large-area proportional counter camera for the U.S. National Small-Angle Neutron Scattering Facility. IEEE Trans. Nucl. Sci. 28(1), 811–815.
Allemand, R., Bourdel, J., Roudaut, E., Convert, P., Ibel, K., Jacobé, J., Cotton, J. P. & Farnoux, B. (1975). Position-sensitive detectors (P.S.D.) for neutron diffraction. Nucl. Instrum. Methods, 126, 29–42.
Baruchel, J., Malgrange, C. & Schlenker, M. (1983). Neutron diffraction topography: using position-sensitive photographic detection to investigate defects and domains in single crystals. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 400–406. London: Academic Press.
Berliner, R., Mildner, D. F. R., Sudol, J. & Taub, H. (1983). Position-sensitive detectors and data collection systems at the University of Missouri Research Reactor Facility. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 120–128. London: Academic Press.
Boie, R. A., Fischer, J., Inagaki, Y., Merritt, F. C., Okuno, H. & Radeka, V. (1982). Two-dimensional high precision thermal neutron detector. Nucl. Instrum. Methods, 200, 533–545.
Borkowski, C. J. & Kopp, M. K. (1975). Design and properties of position-sensitive proportional counters using resistance capacitance position encoding. Rev. Sci. Instrum. 46, 951–962.
Convert, P. & Chieux, P. (1986). From BF3 counter to PSD. An impressive and continuous increase of the data acquisition rate. Fifty years of neutron diffraction, edited by G. E. Bacon, pp. 218–227. Bristol: Adam Hilger.
Convert, P. & Forsyth, J. B. (1983). Position-sensitive detection of thermal neutrons: Part 1, Introduction. Position-sensitive detection of thermal neutrons, pp. 1–90. London: Academic Press.
Fischer, J., Radeka, V. & Boie, R. A. (1983). High position resolution and accuracy in 3He two-dimensional thermal neutron PSDs. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 129–140. London: Academic Press.
Hohlwein, D. (1983). Photographic methods in neutron scattering. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 379–390. London: Academic Press.
Ibel, K. (1976). The neutron small-angle camera D11 at the high-flux reactor, Grenoble. J. Appl. Cryst. 9, 296–309.
Institut Laue–Langevin (1988). Guide to neutron research facilities at the ILL. Grenoble: Institut Laue–Langevin.
Isis (1992). User Guide. Didcot: Rutherford Appleton Laboratory.
Kurz, R. & Schelten, J. (1983). Properties of various scintillators for thermal neutron detection. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 192–196. London: Academic Press.
Naday, I. & Schaefer, W. (1983). A new processing method and gain stabilisation for scintillation position-sensitive detectors. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 197–202. London: Academic Press.
Roudaut, E. (1983). Evolution of position-sensitive detectors for neutron diffraction experiments from 1966 to 1982 in the Nuclear Centre of Grenoble. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 294–301. London: Academic Press.
Schaefer, W., Naday, I. & Will, G. (1983). Neutron powder diffractometry with the linear position-sensitive scintillation detector. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 209–214. London: Academic Press.
Strauss, M. G., Brenner, R., Chou, H. P., Schultz, A. J. & Roche, C. T. (1983). Spatial resolution of neutron position scintillation detectors. Position-sensitive detection of thermal neutrons, edited by P. Convert & J. B. Forsyth, pp. 175–187. London: Academic Press.
Strauss, M. G., Brenner, R., Lynch, F. J. & Morgan, C. B. (1981). 2-D position-sensitive scintillation detector for neutrons. IEEE Trans. Nucl. Sci. 28(1), 800–806.
Thomas, P. (1972). Production of sensitive converter screens for thermal neutron diffraction patterns. J. Appl. Cryst. 5, 373–374.
Whaling, W. (1958). The energy loss of charged particles in matter. Handbuch der Physik, Vol. 34. Corpuscles and radiation in matter II, edited by S. Flugge, pp. 193–217. Berlin: Springer-Verlag.
Windsor, C. G. (1981). Pulsed neutron scattering. London: Taylor and Francis.
Wolf, R. S. (1974). Measurement of the gas constants for various proportional counter gas mixtures. Nucl. Instrum. Methods, 115, 461–463.