Section 2.2.2.2.3. Tuning

A. Fitcha*

aESRF, 71 Avenue des Martyrs, CS40220, 38043 Grenoble Cedex 9, France
Correspondence e-mail: fitch@esrf.fr

2.2.2.2.3. Tuning

| top | pdf |

For insertion devices the magnetic field can be modified by changing the vertical distance between the magnetic poles. By opening the gap, the magnetic field and K decrease following[B_0 \simeq B_r \exp(-\pi G/\lambda_u),]where Br is proportional to the remanent magnetic field, which depends upon the nature of the magnets used in the insertion device, and G is the magnetic gap. Decreasing K for an undulator means that the energy of the fundamental harmonic increases; however, this is at the expense of the intensities of the higher harmonics. Thus the insertion device can be tuned to produce high intensity at the wavelength most suitable for a particular measurement. The smallest gap possible for a device depends on the design of the storage-ring vacuum vessel in which the electrons circulate. It is difficult to have a vessel smaller than about 10 mm high, and hence for an externally applied field a minimum magnetic gap of about 11 mm is to be expected. For smaller gaps, the magnets must be taken into the vacuum of the storage ring, a so-called `in-vacuum' insertion device.