2.7.5. Variable-temperature high-pressure devices

| top | pdf |

One of the most common interests in extreme conditions combines high pressure and high temperature. Several techniques for simultaneously controlling both pressure and temperature have been developed (Fei & Wang, 2000[link]). The DAC can be heated externally (with respect to the sample chamber between the anvils' culets) when the entire DAC is placed in an oven or in a hot stream of air from an electrical heater (Fourme, 1968[link]; Allan & Clark, 1999[link]; Podsiadło & Katrusiak, 2008[link]; Bujak et al., 2008[link]). External resistance-wire heaters placed immediately around the diamond anvils and the gasket are often used (Bassett & Takahashi, 1965[link]; Takahashi et al., 1982[link]; Adams & Christy, 1992[link]; Eremets, 1996[link]; Moore et al., 1970[link]; Hazen & Finger, 1982[link]; Besson, 1997[link]; Dubrovinskaia & Dubrovinsky, 2003[link]; Fei & Wang, 2000[link]). External heating can routinely operate up to about 673 K. Its main advantages are stability, reliable measurement of temperature and high homogeneity of temperature in the chamber. The disadvantages include the relatively low temperature range and the large mass of the DAC mechanical parts that are heated. Their thermal expansion can cause loss of pressure. This does not apply to the membrane DAC, where a constant thrust from the membrane is transmitted to the anvils. A sophisticated externally heated DAC in an atmosphere of inert gases is capable of operating between 83 and 1473 K (Bassett et al., 1993[link]).

A very small turnbuckle DAC, about 6 mm in diameter, was originally constructed of plastic and hardened beryllium–copper alloy (BERYLCO 25) in order to perform magnetic measurements at low temperature in the small bore of a superconductive quantum interference device (SQUID) (Graf et al., 2011[link]; Giriat et al., 2010[link]). These are at present the smallest designs that can be used for X-ray diffraction studies, with the whole DAC cooled by commercial low-temperature gas-stream attachments. Alireza & Lonzarich (2009[link]) built another miniature DAC for high-pressure magnetic measurements in a SQUID.

Temperatures of several thousand kelvin can be achieved by internal heating, where the sample absorbs the focused light beam of a laser (Bassett, 2001[link]; Ming & Bassett, 1974[link]; Shen et al., 1996[link]) or is heated by a thin wire passing through the chamber or its immediate surroundings, either in the gasket walls (Boehler et al., 1986[link]; Mao et al., 1987[link]; Zha & Bassett, 2003[link]; Dubrovinsky et al., 1998[link]) or in the culets of intelligent diamond anvils (Bureau et al., 2006[link]). Composite resistance gaskets, with a platinum chamber wall acting as a 35 W resistance heater, can increase the temperature to over 2273 K (Miletich et al., 2000[link], 2009[link]). Laser beam(s) focused through the DAC anvil(s) onto the sample (Boehler et al., 2001[link]) can heat it to over 3273 K. This requires that the laser beam, or several beams, or a fraction of their energy, be absorbed in the sample. In order to increase the absorption, the sample can be mixed with another compound, for example gold powder. The main disadvantage of laser heating is inhomogeneous distribution of the temperature within the sample.

Much smaller temperature gradients, of a few kelvin at 2773 K, can be obtained in large-volume presses (LVPs). The multi-anvil LVP has traditionally been applied for the synthesis of diamond, which requires stable conditions of both high pressure and high temperature (Hazen, 1999[link]; Liebermann, 2011[link]). In the LVP, a resistance heater installed inside the chamber can provide stable control of the temperature for days, while the pressure is controlled by a hydraulic press. Owing to the large sample volume, the diffraction pattern can be quickly recorded. Most often, energy-dispersive diffraction is applied for the beams entering and leaving the pressure chamber through the gasket material between the anvils. LVPs are generally very large and heavy, which contrasts with the compact construction of the Paris–Edinburgh and Kurchatov–LLB pressure cells (Besson et al., 1992[link]; Goncharenko, 2004[link], 2006[link]). Both these opposed-anvil cells can be placed in cryostats, and they can be used for either energy- or angle-dispersive diffraction of neutrons or X-rays. The Kurchatov–LLB cell has been optimized for neutron diffraction studies of magnetic structures at high pressure and low temperature (Goncharenko & Mirebeau, 1998[link]; Goncharenko et al., 1995[link]).

References

Adams, D. M. & Christy, A. G. (1992). Materials for high-temperature diamond-anvil cells. High Press. Res. 8, 685–689.Google Scholar
Alireza, P. L. & Lonzarich, G. G. (2009). Miniature anvil cell for high-pressure measurements in a commercial superconducting quantum interference device magnetometer. Rev. Sci. Instrum. 80, 023906.Google Scholar
Allan, D. R. & Clark, S. J. (1999). Impeded dimer formation in the high-pressure crystal structure of formic acid. Phys. Rev. Lett. 82, 3464–3467.Google Scholar
Bassett, W. A. (2001). The birth and development of laser heating in diamond anvil cells. Rev. Sci. Instrum. 72, 1270–1272.Google Scholar
Bassett, W. A., Shen, A. H., Bucknum, M. & Chou, I.-M. (1993). A new diamond anvil cell for hydrothermal studies to 2.5 GPa and from −190 to 1200°C. Rev. Sci. Instrum. 64, 2340–2345.Google Scholar
Bassett, W. A. & Takahashi, T. (1965). Silver iodide polymorphs. Am. Mineral. 50, 1576–1594.Google Scholar
Besson, J. M. (1997). Pressure generation. In High-Pressure Techniques in Chemistry and Physics. A Practical Approach, edited by W. B. Holzapfel & N. S. Isaacs, pp. 1–45. Oxford University Press.Google Scholar
Besson, J. M., Nelmes, R. J., Hamel, G., Loveday, J. S., Weill, G. & Hull, S. (1992). Neutron powder diffraction above 10 GPa. Physica B, 180–181, 907–910.Google Scholar
Boehler, R., Nicol, M., Zha, C. S. & Jonson, M. L. (1986). Resistance heating of Fe and W in diamond anvil cells. Physica B, 139–140, 916–918.Google Scholar
Boehler, R., Ross, M. P. & Boercker, D. B. (2001). High-pressure melting curves of argon, krypton, and xenon: deviation from corresponding states theory. Phys. Rev. Lett. 86, 5731–5734.Google Scholar
Bujak, M., Podsiadło, M. & Katrusiak, A. (2008). Energetics of conformational conversion between 1,1,2-trichloroethane polymorphs. Chem. Commun. pp. 4439–4441.Google Scholar
Bureau, H., Burchard, M., Kubsky, S., Henry, S., Gonde, C., Zaitsev, A. & Meijer, J. (2006). Intelligent anvils applied to experimental investigations: state of the art. High Press. Res. 26, 251–265.Google Scholar
Dubrovinskaia, N. & Dubrovinsky, L. S. (2003). Whole-cell heater for the diamond anvil cell. Rev. Sci. Instrum. 74, 3433–3437.Google Scholar
Dubrovinsky, L. S., Saxena, S. K. & Lazor, P. (1998). High-pressure and high-temperature in situ X-ray diffraction study of iron and corundum to 68 GPa using an internally heated diamond anvil cell. Phys. Chem. Miner. 25, 434–441.Google Scholar
Eremets, M. (1996). High Pressure Experimental Methods. New York: Oxford University Press.Google Scholar
Fei, Y. & Wang, Y. (2000). High-pressure and high-temperature powder diffraction. Rev. Mineral. Geochem. 41, 521–557.Google Scholar
Fourme, R. (1968). Appareillage pour études radiocristallographiques sous pression et à température variable. J. Appl. Cryst. 1, 23–30.Google Scholar
Giriat, G., Wang, W., Attfield, J. P., Huxley, A. D. & Kamenev, K. V. (2010). Turnbuckle diamond anvil cell for high-pressure measurements in a superconducting quantum interference device magnetometer. Rev. Sci. Instrum. 81, 073905.Google Scholar
Goncharenko, I. N. (2004). Magnetic properties of crystals and their studies at high pressure conditions. In High-Pressure Crystallography, edited by A. Katrusiak & P. F. McMillan, pp. 321–340. Dordrecht: Kluwer.Google Scholar
Goncharenko, I. N. (2006). Magnetic and crystal structures probed by neutrons in 40 GPa pressure range. Acta Cryst. A62, s95.Google Scholar
Goncharenko, I. N., Mignot, J.-M., Andre, G., Lavrova, O. A., Mirebeau, I. & Somenkov, V. A. (1995). Neutron diffraction studies of magnetic structure and phase transitions at very high pressures. High Press. Res. 14, 41–53.Google Scholar
Goncharenko, I. N. & Mirebeau, I. (1998). Magnetic neutron diffraction under very high pressures. Study of europium monochalcogenides. Rev. High Press. Sci. Technol. 7, 475–480.Google Scholar
Graf, D. E., Stillwell, R. L., Purcell, K. M. & Tozer, S. W. (2011). Nonmetallic gasket and miniature plastic turnbuckle diamond anvil cell for pulsed magnetic field studies at cryogenic temperatures. High Press. Res. 31, 533–543.Google Scholar
Hazen, R. M. (1999). The Diamond Makers. Cambridge Unversity Press.Google Scholar
Hazen, R. M. & Finger, L. (1982). Comparative Crystal Chemistry. New York: John Wiley & Sons.Google Scholar
Liebermann, R. C. (2011). Multi-anvil, high pressure apparatus: a half-century of development and progress. High Press. Res. 31, 493–532.Google Scholar
Mao, H. K., Bell, P. & Hadidiacos, C. (1987). Experimental phase relations in iron to 360 kbar, 1400°C, determined in an internally heated diamond-anvil apparatus. In High-Pressure Research in Mineral Physics, edited by M. H. Manghnani & Y. Syono, pp. 135–138. San Francisco: Terrapub/AGU. Google Scholar
Miletich, R., Allan, D. R. & Kuhs, W. F. (2000). High-pressure single crystal techniques. Rev. Mineral. Geochem. 41, 445–519.Google Scholar
Miletich, R., Cinato, D. & Johänntgen, S. (2009). An internally heated composite gasket for diamond-anvil cells using the pressure chamber wall as the heating element. High Press. Res. 29, 290–305.Google Scholar
Ming, L. C. & Bassett, W. A. (1974). Laser heating in the diamond anvil press up to 2000°C sustained and 3000°C pulsed at pressures up to 260 kilobars. Rev. Sci. Instrum. 45, 1115–1118.Google Scholar
Moore, M. J., Sorensen, D. B. & DeVries, R. C. (1970). A simple heating device for diamond anvil high pressure cells. Rev. Sci. Instrum. 41, 1665–1666.Google Scholar
Podsiadło, M. & Katrusiak, A. (2008). Isostructural relations in dihalomethanes and disproportionation of bromoiodomethane. Cryst­EngComm, 10, 1436–1442.Google Scholar
Shen, G., Mao, H. K. & Hemley, R. J. (1996). Laser-heated diamond anvil cell technique: double-sided heating with multimode Nd:YAG laser. Proceedings of the 3rd NIRIM International Symposium on Advanced Materials, ISAM'96, 4–8 March 1996, Tsukuba, Japan, pp. 149–152. Tsukuba: National Institute for Research in Inorganic Materials.Google Scholar
Takahashi, E., Yamada, H. & Ito, E. (1982). An ultrahigh-pressure furnace assembly to 100 kbar and 1500°C with minimum temperature uncertainty. Geophys. Res. Lett. 9, 805–807.Google Scholar
Zha, C. S. & Bassett, W. A. (2003). Internal resistive heating in diamond anvil cell for in situ X-ray diffraction and Raman scattering. Rev. Sci. Instrum. 74, 1255–1262.Google Scholar