your search
 Results for DC.creator="E." AND DC.creator="F." AND DC.creator="Eikenberry"   page 1 of 2 pages.
CCD detectors
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, ch. 7.2, pp. 183-188 [ doi:10.1107/97809553602060000821 ]
array detectors (see Section 7.1.4 in Chapter 7.1). References Barna, S. L., Tate, M. W., Gruner, S. M. & Eikenberry, E. F. (1999). Calibration procedures for charge-coupled device X-ray detectors . Rev. Sci ...

Flat-field corrections
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.3.4, pp. 185-186 [ doi:10.1107/97809553602060000821 ]
in the phosphor stand out clearly when the data are corrected using factors derived from the wrong X-ray energy. References Gruner, S. M., Barna, S. L., Wall, M. E., Tate, M. W. & Eikenberry, E. F. (1993). Characterization ...
     [more results from section 7.2.3 in volume F]

Applications to macromolecular crystallography
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.5, pp. 187-187 [ doi:10.1107/97809553602060000821 ]


CCD detector assembly
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.2, pp. 183-184 [ doi:10.1107/97809553602060000821 ]
Philips Res. Rep. 29, 353–362. Google Scholar Tate, M. W., Eikenberry, E. F. & Gruner, S. M. (1997). Coupling format variations in X-ray detectors based on charge-coupled devices . Rev. Sci. Instrum. 68, 47–54. Google ...

Detector system integration
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.4, pp. 186-187 [ doi:10.1107/97809553602060000821 ]


Future of CCD detectors
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.6, pp. 187-187 [ doi:10.1107/97809553602060000821 ]


Overview
Tate, M. W., Eikenberry, E. F. and Gruner, S. M., International Tables for Crystallography (2012). Vol. F, Section 7.2.1, pp. 183-183 [ doi:10.1107/97809553602060000821 ]
Eikenberry, E. F., Tate, M. W., Belmonte, A. L., Lowrance, J. L., Bilderback, D. & Gruner, S. M. (1991). A direct-coupled detector for synchrotron X-radiation using a large format CCD imaging array . IEEE Trans. Nucl. Sci. 38, 110–118 ...

Comparison of X-ray detectors
Gruner, S. M., Eikenberry, E. F. and Tate, M. W., International Tables for Crystallography (2012). Vol. F, ch. 7.1, pp. 177-182 [ doi:10.1107/97809553602060000820 ]
Wixted, R. L., Eikenberry, E. F. & Gruner, S. M. (1997). Characterization of prototype pixel array detector (PAD) for use in microsecond framing time-resolved X-ray diffraction studies . IEEE Trans. Nucl. Sci. 44, 950–956. Google Scholar ...

Counting and integrating detectors
Gruner, S. M., Eikenberry, E. F. and Tate, M. W., International Tables for Crystallography (2012). Vol. F, Section 7.1.3.2, pp. 179-181 [ doi:10.1107/97809553602060000820 ]
Eikenberry, E. F., Tate, M. W., Bilderback, D. H. & Gruner, S. M. (1992). X-ray detectors: comparison of film, storage phosphors and CCD detectors . Inst. Phys. Conf. Ser. 121, 273–280. Google Scholar Farrell, R., Vanderpuye, K ...
     [more results from section 7.1.3 in volume F]

Commonly used detectors: general considerations
Gruner, S. M., Eikenberry, E. F. and Tate, M. W., International Tables for Crystallography (2012). Vol. F, Section 7.1.1, pp. 177-178 [ doi:10.1107/97809553602060000820 ]
into an application with the appropriate analysis software and whether the control software is well interfaced to the other X-ray hardware. References Barna, S. L., Tate, M. W., Gruner, S. M. & Eikenberry, E. F. (1999). Calibration ...

Page: 1 2 Next powered by swish-e
























































to end of page
to top of page