modify your search
 Results for DC.creator="K." AND DC.creator="Knorr"   page 1 of 2 pages.
Quantitative phase analysis
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, ch. 3.9, pp. 344-373 [ doi:10.1107/97809553602060000954 ]
... Hill, 1991 ; Hill & Howard, 1987 ; O'Connor & Raven, 1988 ) where K is an 'experiment constant' used to put W[alpha] on ... Connor & Raven (1988 ) and Bish & Howard (1988 ) have shown that K is dependent only on the instrumental conditions and is independent ... related parameters. Therefore a single measurement is sufficient to determine K for a given instrument configuration and set of data- ...

Phase-specific methods: diffraction SRMs, round-robin samples and synthetic mixtures
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.10.3.6, pp. 369-370 [ doi:10.1107/97809553602060000954 ]
... Portland cements. J. Appl. Cryst. 42, 906-916.GoogleScholar McCarty, D. K. (2002). Quantitative mineral analysis of clay-bearing mixtures: The ... J. Appl. Cryst. 34, 409-426.GoogleScholar Omotoso, O., McCarty, D. K., Hillier, S. & Kleeberg, R. (2006). Some successful approaches to ...
     [more results from section 3.9.10 in volume H]

QPA using energy-dispersive diffraction data
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.9, pp. 362-364 [ doi:10.1107/97809553602060000954 ]
... Cryst. 11, 165-172.GoogleScholar Hall, C., Barnes, P., Cockcroft, J. K., Colston, S. L., Häusermann, D., Jacques, S. D. M. ... M. J., Madsen, I. C., Scarlett, N. V. Y., McGregor, K., Riley, D. P., Snook, G. A., Urban, A. J., Connolley ... I. C., Evans, J. S. O., Coelho, A. A., McGregor, K., Rowles, M., Lanyon, M. R. & Urban, A. J. (2009) ...

QPA using neutron diffraction data
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.8, p. 362 [ doi:10.1107/97809553602060000954 ]
... T. A., Nicol, J. M., Wilkinson, A. P. & Cheetham, A. K. (1992). Determination of complex structures by combined neutron and ...

Data analysis
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.7.1, pp. 361-362 [ doi:10.1107/97809553602060000954 ]
... component analysis. Figure 3.9.14 | | Raw in situ XRD data (Co K[alpha] radiation) collected during the synthesis of the iron-ore ...
     [more results from section 3.9.7 in volume H]

Quantitative determination of amorphous material
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.6.3, pp. 360-361 [ doi:10.1107/97809553602060000954 ]
... Figure 3.9.13 | | Output of Rietveld refinement of XRD data (Cu K[alpha] radiation) for a synthetic sample containing a mixture crystalline ...
     [more results from section 3.9.6 in volume H]

Experiment constant - a whole-sample approach
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.5.3, pp. 355-356 [ doi:10.1107/97809553602060000954 ]
... sample approach Earlier discussion has noted that the experiment constant K used in equation (3.9.21) can be determined using (i) a ... approaches are not always effective in producing reliable values of K because the methodology assumes that the mass of sample contributing ... hence on the observed intensity and the derived values of K. Therefore, a K value determined from one capillary sample ...
     [more results from section 3.9.5 in volume H]

Rietveld-based methods
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.4.5, pp. 352-353 [ doi:10.1107/97809553602060000954 ]
... . In this case, the value for the instrument constant, K, can be derived using the Rietveld scale factor, ZMV and ... an arbitrary value of unity for both the determination of K and all subsequent analyses, since the overall chemical content of ... the `instrument configuration'. This requires a modification of the K value and subsequent calculation of concentration to compensate for ...
     [more results from section 3.9.4 in volume H]

Rietveld-based QPA
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.3.6, pp. 348-350 [ doi:10.1107/97809553602060000954 ]
... Hill, 1991 ; Hill & Howard, 1987 ; O'Connor & Raven, 1988 ) where K is an 'experiment constant' used to put W[alpha] on ... Connor & Raven (1988 ) and Bish & Howard (1988 ) have shown that K is dependent only on the instrumental conditions and is independent ... related parameters. Therefore a single measurement is sufficient to determine K for a given instrument configuration and set of data- ...
     [more results from section 3.9.3 in volume H]

Phase analysis
Madsen, I., Scarlett, N., Kleeberg, R. and Knorr, K.  International Tables for Crystallography (2018). Vol. H, Section 3.9.2, pp. 344-345 [ doi:10.1107/97809553602060000954 ]
Phase analysis 3.9.2. Phase analysis There are a number of traditional methods for the estimation of phase abundance in multiphase materials (Zevin & Kimmel, 1995 ). In summary, these can be divided into two groups: (1) Indirect methods - these are usually based on the measurement of total chemical composition, which is then ...

Page: 1 2 Next powered by swish-e
























































to end of page
to top of page