modify your search
 Results for DC.creator="A." AND DC.creator="Kern" in section 2.1.3 of volume H
Recent years
Kern, A.  International Tables for Crystallography (2018). Vol. H, Section 2.1.3.2, p. 28 [ doi:10.1107/97809553602060000936 ]
... the 1990s, more and more laboratories started to deal with a full range of materials and related applications - from powders through ... quality requirements. The growing need for multipurpose instrumentation led to a new generation of X-ray diffractometers in the late 1990s, from all of the major manufacturers, based on a platform concept covering all relevant beam-path components including ...

Diffractometers
Kern, A.  International Tables for Crystallography (2018). Vol. H, Section 2.1.3.1.2, pp. 27-28 [ doi:10.1107/97809553602060000936 ]
... shortcomings led to the idea of replacing the film with a photon counter (most commonly utilizing the Geiger-Müller counter at that time) and thus to the development of a device called a `diffractometer'. The design resembled that of the Bragg ...

Film cameras
Kern, A.  International Tables for Crystallography (2018). Vol. H, Section 2.1.3.1.1, pp. 26-27 [ doi:10.1107/97809553602060000936 ]
... developed independently by Debye & Scherrer (1916 ) and Hull (1917 ), using a film to detect the scattered X-rays, with the instrument ... improved resolution, the intensity was also greatly increased by using a para-focusing arrangement using an X-ray source and specimen ... interest, and developed into the powder diffraction method, making it a fundamental tool for material scientists. However, while classic film ...

From film cameras to diffractometers
Kern, A.  International Tables for Crystallography (2018). Vol. H, Section 2.1.3.1, pp. 26-28 [ doi:10.1107/97809553602060000936 ]
... developed independently by Debye & Scherrer (1916 ) and Hull (1917 ), using a film to detect the scattered X-rays, with the instrument ... improved resolution, the intensity was also greatly increased by using a para-focusing arrangement using an X-ray source and specimen ... interest, and developed into the powder diffraction method, making it a fundamental tool for material scientists. However, while classic film ...

Historical overview
Kern, A.  International Tables for Crystallography (2018). Vol. H, Section 2.1.3, pp. 26-28 [ doi:10.1107/97809553602060000936 ]
... developed independently by Debye & Scherrer (1916 ) and Hull (1917 ), using a film to detect the scattered X-rays, with the instrument ... improved resolution, the intensity was also greatly increased by using a para-focusing arrangement using an X-ray source and specimen ... interest, and developed into the powder diffraction method, making it a fundamental tool for material scientists. However, while classic film ...

powered by swish-e
























































to end of page
to top of page