modify your search
 Results for DC.creator="U." AND DC.creator="W." AND DC.creator="Arndt" in section 4.2.1 of volume C
Generation of X-rays
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1, pp. 191-200 [ doi:10.1107/97809553602060000592 ]
... characteristic X-ray flux from Cr, Cu, Mo, Ag and W targets has been carried out by Honkimaki, Sleight & Suortti (1990 ... number of other storage rings. In this table, BM and W signify bending-magnet and wiggler beam lines, respectively, and is ... 0.100 0.008 0.9 14 8 1012 1 1013 (2) ESRF W 30 100 5.0 11.56 0.062 0.040 0.016 0.5 24 ...

Plasma X-ray sources
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.6, pp. 198-199 [ doi:10.1107/97809553602060000592 ]
... optics. Phys. Fluids B (Plasma Phys.), 3, 2414-2419. Seka, W., Soures, J. M., Lewis, O., Bunkenburg, J., Brown, D., Jacobs ... design and performance characteristics. Appl. Opt. 19, 409-419. Seka, W., Soures, J. M., Lund, L. & Craxton, R. S. (1981). ... Goldman, L. M., McCrory, L. R., Richardson, M. C., Seka, W., Shvarts, D. & Soures, J. M. (1981). Characteristics of ...

Synchrotron-radiation sources
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.5, pp. 196-198 [ doi:10.1107/97809553602060000592 ]
... number of other storage rings. In this table, BM and W signify bending-magnet and wiggler beam lines, respectively, and is ... 0.100 0.008 0.9 14 8 1012 1 1013 (2) ESRF W 30 100 5.0 11.56 0.062 0.040 0.016 0.5 24 2.4 ... 0.04 8.0 1.5 2.4 1012 5 1010 (4) ADONE (Frascati) W 6 100 1.5 2.6 1.4 0.24 0.08 4.3 3 ...

Radioactive X-ray sources
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.4, pp. 195-196 [ doi:10.1107/97809553602060000592 ]
Radioactive X-ray sources 4.2.1.4. Radioactive X-ray sources Radioactive sources of X-rays are mainly of interest to crystallographers for the calibration of X-ray detectors where they have the great advantage of being completely stable with time, or at least of having an accurately known decay rate. For some ...

Power dissipation in the anode
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.3.1, p. 195 [ doi:10.1107/97809553602060000592 ]
... cooling can be dispensed with. References Cosslett, V. E. & Nixon, W. C. (1951). X-ray shadow microscope. Nature (London), 168, 24-25. Cosslett, V. E. & Nixon, W. C. (1960). X-ray microscopy, pp. 217-222. Cambridge ... Proc. R. Soc. London Ser. A, 132, 646-649. Oosterkamp, W. J. (1948a). The heat dissipation in the anode ...

X-ray tubes
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.3, pp. 193-195 [ doi:10.1107/97809553602060000592 ]
... Phys. Soc. London, 46, 703-712. Cosslett, V. E. & Nixon, W. C. (1951). X-ray shadow microscope. Nature (London), 168, 24-25. Cosslett, V. E. & Nixon, W. C. (1960). X-ray microscopy, pp. 217-222. Cambridge University Press. Ehrenberg, W. & Spear, W. E. (1951). An electrostatic focusing system ...

The continuous spectrum
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.2, pp. 192-193 [ doi:10.1107/97809553602060000592 ]
The continuous spectrum 4.2.1.2. The continuous spectrum The shape of the continuous spectrum from a thick target is very simple: , the energy per unit frequency band in the spectrum, is given by the expression derived by Kramers (1923): where Z is the atomic number of the target and A and B ...

The intensity of characteristic lines
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.1.1, pp. 191-192 [ doi:10.1107/97809553602060000592 ]
... characteristic X-ray flux from Cr, Cu, Mo, Ag and W targets has been carried out by Honkimaki, Sleight & Suortti (1990 ... X-ray flux from sealed Cr, Cu, Mo, Ag and W tubes. J. Appl. Cryst. 23, 412-417. Metchnik, V. & Tomlin ...

The characteristic line spectrum
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.1, pp. 191-192 [ doi:10.1107/97809553602060000592 ]
... characteristic X-ray flux from Cr, Cu, Mo, Ag and W targets has been carried out by Honkimaki, Sleight & Suortti (1990 ... X-ray flux from sealed Cr, Cu, Mo, Ag and W tubes. J. Appl. Cryst. 23, 412-417. Jenkins, R., Manne ...

Other sources of X-rays
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 4.2.1.7, pp. 199-200 [ doi:10.1107/97809553602060000592 ]
... with synchrotron-radiation sources. References Fiorito, R. B., Rule, D. W., Piestrup, M. A., Li, Q., Ho, A. H. & Maruyama, X. ... Piestrup, M. A., Li, Q., Fiorito, R. B. & Rule, D. W. (1993). A compact tunable X-ray source based on ...

powered by swish-e
























































to end of page
to top of page