modify your search
 Results for DC.creator="U." AND DC.creator="W." AND DC.creator="Arndt" in section 7.1.6 of volume C   page 1 of 3 pages.
Position-sensitive detectors
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6, pp. 623-633 [ doi:10.1107/97809553602060000604 ]
... the arrival of X-ray photons (Hendricks, 1976; Hendrix, 1982; Arndt, 1986). In addition, imaging detectors have found increasing use ... any, of the source, as, for example, with storage rings (Arndt, 1978). Counting losses can affect the behaviour of detectors ... a reduced DQE. This is valid for X-ray film (Arndt, Gilmore & Wonacott, 1977), for television detectors (Arndt, 1984), for ...

TV camera tubes
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.5.4, p. 632 [ doi:10.1107/97809553602060000604 ]
TV camera tubes 7.1.6.5.4. TV camera tubes Vacuum-tube television cameras have been largely replaced by semiconductor devices but of the former the preferred tube for use in an X-ray detector is still the silicon-intensifier-target (SIT) tube (Santilli & Conger, 1972). It has an adequate resolution for images ...

Image intensifiers
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.5.3, p. 632 [ doi:10.1107/97809553602060000604 ]
... low-light-level TV camera tube in the next stage (Arndt & Gilmore, 1979) or of two or more intensifiers of this ... them to a TV pick-up device. References Airey, R. W. & Morgan, B. L. (1985). A microchannel plate image intensifier ... noise-limited images. IEE Conf. Publ. (London), 253, 5-7. Arndt, U. W. & Gilmore, D. J. (1979). X-ray ...

Light coupling
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.5.2, p. 632 [ doi:10.1107/97809553602060000604 ]
... the first photocathode in order to achieve a high DQE (Arndt & Gilmore, 1979). The best photocathodes have a yield of ... area X-ray detectors. J. Synchrotron Rad. 1, 54-62. Arndt, U. W. & Gilmore, D. J. (1979). X-ray television ...

X-ray phosphors
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.5.1, p. 631 [ doi:10.1107/97809553602060000604 ]
X-ray phosphors 7.1.6.5.1. X-ray phosphors The incoming X-rays are converted to light in a phosphor that is coupled to the first photocathode of the system. Both polycrystalline and monocrystalline phosphors are used for X-ray detection. The former give a higher light output but have a limited resolution ...

Television area detectors with external phosphor
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.5, pp. 630-632 [ doi:10.1107/97809553602060000604 ]
... coupled via demagnifying optics to a sensitive television camera tube (Arndt & Gilmore, 1979; Arndt, 1982, 1985; Arndt & In't Veld, 1988; Kalata, 1982, 1985; Gruner, Milch & ...

Devices with an X-ray-sensitive photocathode
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.4, p. 630 [ doi:10.1107/97809553602060000604 ]
... Maruyama, H., Goto, K., Fujimoto, I., Shidara, K., Kawamura, T. W., Hirai, T., Sakai, H. & Chikawa, J. (1993). Characteristics of ...

Electron-sensitive PSD's
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.3.3, p. 630 [ doi:10.1107/97809553602060000604 ]
Electron-sensitive PSD's 7.1.6.3.3. Electron-sensitive PSD's In image intensifiers, an output image is produced on a phosphor screen by electrons with an energy of a few keV. A promising device with direct positional read out consists of a demagnifying intensifier in which the phosphor is replaced by a ...

Light-sensitive semiconductor PSD's
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.3.2, p. 630 [ doi:10.1107/97809553602060000604 ]
... large number of pixels. Table 7.1.6.2| | X-ray phosphors (from Arndt, 1982) PhosphorTypeBulk densityNo. of photons per 8 keV quantumMax. emission ... area X-ray detectors. J. Synchrotron Rad. 1, 54-62. Arndt, U. W. (1982). X-ray television area detectors. Nucl. ...

X-ray-sensitive semiconductor PSD's
Arndt, U. W.  International Tables for Crystallography (2006). Vol. C, Section 7.1.6.3.1, pp. 629-630 [ doi:10.1107/97809553602060000604 ]
... problems discussed above (Deckman & Gruner, 1986). References Deckman, H. W. & Gruner, S. M. (1986). Formal alterations in CCD-based ... CCD's. IEE Conf. Publ. (London), 253, Suppl. Meyer-Ilse, W., Wilhelm, T. & Guttmann, P. (1993). Thinned back-illuminated CCD ...

Page: 1 2 3 Next powered by swish-e
























































to end of page
to top of page